غانغبوالتكنولوجيا البيئية
Bulk cargo ship loader boom and belt conveyor gallery along a port terminal pier

Port & Terminal

Port & Terminal Treatment & Conveying Configuration

Fugitive dust from bulk cargo unloading, transfer towers and stockpiles, with belt and bucket conveying.

Working condition

Typical problems in this sector

  • Fugitive dust from ship unloading, transfer towers and stockpiles spreads across the yard in wind.
  • Long conveying distances need reliable belt systems with dust tight transfer points.
  • Coastal atmosphere accelerates corrosion of structures and equipment.
  • Water spray suppression alone cannot control fine dust at transfer points.

Recommended configuration

Stage by stage equipment selection

Each row shows the process stage, the machine we normally select and the point that decides whether it performs on site.

Recommended equipment configuration for Port & Terminal
Process stageRecommended equipmentSelection point
Unloading and transfer dustBaghouse or cartridge collector at transfer towersGP-LCM / GP-PPC SeriesLocal capture at each transfer point, collector sized for the chute displacement air.
Long distance transportBelt conveyor with covers and walkwaysGP-DTII / GP-TD75 SeriesGalvanised structure for coastal sites, skirting and belt cleaner at loading points.
Vertical lifting to siloBucket elevatorGP-NE / GP-TD SeriesSealed casing with dust extraction connection to the collector.
Silo dischargeRotary airlock valve and screw conveyorGP-YJD-A / GP-YJD-B SeriesAirtight discharge for truck loading, wear resistant rotor for abrasive cargo.
Yard dust suppressionSpray scrubber and water spray systemGP-PP / GP-FRP SeriesCombined dry collection and wet suppression where cargo is water tolerant.

Energy

Energy saving measures for this sector

  • Belt conveyor drives benefit from VFD control when throughput varies with vessel schedule.
  • Regenerative drives can recover energy on downhill conveying sections.

Port dust limits are set by the port authority and local environmental regulation. Capture efficiency depends on enclosure quality and wind condition at the yard.

Related projects

Delivered in Port & Terminal

Technical reading

Articles related to this sector

Planning a project in Port & Terminal?

Send air volume, dust or gas data, temperature and available space. Our engineers reply with a configuration proposal and a budget quotation within 1 working day.

نستخدم ملفات تعريف ارتباط أساسية فقط لتشغيل هذا الموقع وحفظ لغة اختيارك وقرار الموافقة. لا يتم تعيين ملفات تعريف ارتباط للإعلان أو التتبع عبر المواقع. اقرأ سياسة الخصوصية سياسة الخصوصية.