GANGPUTeknologi Lingkungan
Variable frequency drive cabinet installed for industrial fan and pump energy saving retrofit

Industrial Energy Saving Retrofit

Fan & Pump VFD Energy Saving Retrofit

GP-VFD Series

Variable frequency drive retrofit for large induced draft fans, blowers and water pumps with throttling losses removed.

Motor power
15 - 2,500 kW
Voltage
380 V / 690 V / 3 kV / 6 kV / 10 kV
Typical saving
15 - 40% depending on load profile
Control
Local, remote, DCS or pressure/flow closed loop

Data needed for an accurate quotation

  • Air or gas volume at operating temperature
  • Dust or pollutant type and concentration
  • Required outlet concentration or standard
  • Available plot size and power supply

Technical parameters

Grouped specification sheet

Technical parameters
Drive
Motor power range15 - 2,500 kW
Voltage classLV 380 / 690 V, MV 3 / 6 / 10 kV
Control modeV/F, sensorless vector, closed loop with pressure or flow
ProtectionOver current, over voltage, phase loss, over temperature, ground fault
Retrofit scope
SurveyLoad profile, operating hours, throttling and valve position measurement
DesignDrive sizing, harmonic analysis, bypass and interlock scheme
InstallationCabinet, cables, sensors, cooling and civil works
VerificationBefore and after power metering with test report

Values shown are the standard manufacturing range. Final parameters are calculated from your gas volume, dust or pollutant load, temperature and the emission standard in force at your site.

Customisation options

  • Bypass cabinet for continuous operation during failure
  • Harmonic filter or multi-pulse rectifier
  • Remote monitoring and energy metering
  • Outdoor cabinet with cooling and dust protection

Export packing & delivery

  • Cabinets in wooden cases with shock indicators
  • Spare parts and documents in separate boxes

Drawings, assembly sequence, manual and test records are supplied with every shipment. On-site engineer dispatch can be arranged for complete system projects.

Read the export and installation checklist

Matched equipment

Systems usually supplied together

Collector, fan, discharge valve and conveying equipment designed as one train so interfaces and spares stay consistent.

Industrial centrifugal induced draft fan with motor on a common base frame

Industrial Dust Collection

Industrial Centrifugal Induced Draft Fan

GP-4-73 / GP-9-19 Series

High pressure and high temperature centrifugal fans for dust collection, flue gas extraction and material conveying systems.

Air volume
5,000 - 400,000 m³/h
Total pressure
1,000 - 12,000 Pa
Motor power
7.5 - 1,250 kW
Gas temperature
≤ 450 °C with hot gas design
Industrial plant energy monitoring control room with consumption dashboards

Industrial Energy Saving Retrofit

Plant-Wide Energy Audit & Optimisation

GP-EMS Service

Whole plant energy diagnosis covering compressed air, steam, fans, pumps, lighting and production line scheduling.

Scope
Compressed air, steam, fans, pumps, lighting, scheduling
Deliverable
Audit report, saving calculation, retrofit plan
Metering
Sub-metering per workshop and key equipment
Follow-up
Before and after verification with test data

Related technical articles

Selection notes for this equipment

Inquiry for Fan & Pump VFD Energy Saving Retrofit

The product name and model are attached automatically. Add your gas volume, dust or pollutant data and required outlet value.

Prefer a direct channel? Email szamtx@163.com or scan the WhatsApp QR code in the floating button.

Tell us your plant condition, we will size the system

Send air volume, dust or gas data, temperature and available space. Our engineers reply with a configuration proposal and a budget quotation within 1 working day.